Bayer ADVIA 1650 Chemical Analyzer

⌖ Budapest, HU광고 ID: MX-19D4B2A8

광고 개요

주요 정보

카테고리실험실 기기
상태중고 · 정상 작동
연도—
제조사Bayer
모델ADVIA 1650
모델 / 부품 번호ADVIA 1650

전체 기술 사양

카테고리실험실 기기
상태중고 · 정상 작동
연도—
제조사Bayer
모델ADVIA 1650
모델 / 부품 번호ADVIA 1650

광고 정보

설명

Bayer ADVIA 1650 Chemical Analyzer

The ADVIA 1650 has minimal requirements for sample volume (as low as 2 µL/test), reagent consumption (as low as 80 µL/test) and water consumption (25 L/hour) – thus maximizing management efficiency. A rapid, 3-second cycle and system throughput of up to 1650 tests/hour provide powerful high-speed performance, ensure workflow efficiency through peak workloads. Optional universal rack handler facilitates continuous sample feeding for further productivity gains.

Measurement point: 98 detection points/ 6 seconds in 10 minute reaction

Photometer: Concavity diffraction grating, rear spectroscopy system

Measurement wavelength: 14 fixed wavelengths (340, 410 ,451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm), 1 or 2 wavelenth calculation

Light source: 12V, 50W halogen lamp, cooled by forced water circulation

Assay method: Colorimetric assays – Endpoint assays (EPA), Reaction rate assays (RRA), 2-point rate assays (2PA), 3-item simultaneous measurement (parameter independent), Prozone checking (antigen excess check) Substrate depletion check with point forwarding option, Sample blank correction

Reassay mechanism: Automatic or manual (selectable)

Automatic correction: Blood serum blank, cell blank, measurement point change, sample volume change in reassay

Measurement method: Open discrete – Single line, simultaneous, multi item measurement

Throughput rate: Maximum 1650 tests/hour

Throughput rate biochemistry : Maximum 1200 tests/hour

Throughput rate electrolyte: Maximum 450 tests/hour

Sample throughput rate: Maximum 1200 samples/hour

Simultaneous measurement item: Maximum 103 items, normally 50 (main system) + 3 (ISE)

Measurement sample: Blood serum, plasma and urine (method dependent)

Containers: 5 mL, 7mL, 10 mL collection tubes (dead volume for collection tubes is 200 µL)

Cups: 1.8 mL JEOL sample cups (STT only), Hitachi 2 mL sample cups and Immuno 2 mL sample cups in 7 mL (16 x 75 mm) collection tubes (URH) or STT sample adapter (dead volume for sample cups is 50 µL)

No software with the unit.

Reassay mechanism: Automatic or manual (selectable)

Throughput rate: Maximum 1650 tests/hour

Throughput rate biochemistry: Maximum 1200 tests/hour

Throughput rate electrolyte: Maximum 450 tests/hour